“ The Leader in Engineering Service Consultants ”

  • 02 270 8899

Instrumented Static Pile Load Test Wittayu Condominium Project

Division 
Pile Testing  Business Unit
Project Owner/ Client 

Job Types
Instrumented Static Pile Load Test
Location
Witthayu Road, Lumphini Subdistrict, Pathumwan District, Bangkok 
Value of Work
-
Last Year Completed
2025

Instrumented Static Pile Load Test for Bored Pile Dia. 1.80 × 80.00 m
Project: Wittayu Condominium Project, located on Wireless  Road, Lumphini Subdistrict, Pathumwan District, Bangkok.

This testing program involves the Instrumented Static Pile Load Test for bored piles with a Design Load of 2,400 tons (F.S.: 2.0) and a Maximum Target Load of 4,800 tons. The test incorporates specialized instrumentation—including Vibrating Wire Strain Gauges (VWSG), Mechanical Extensometers, and Magnetic Extensometers—to monitor and evaluate load distribution along the pile length under test loading.

The objective is to assess the unit skin friction and end bearing capacity of the pile under various loading stages, providing essential data for project-specific foundation design refinement.

Piling Contractor: Seafco Public Company Limited
Testing Company: STS Corporation Company Limited (Pile Testing Business Unit)